24-28 Sep 2017 Saint Malo (France)

Author index > Zalden Peter

Germanium coordination and bond distances in compressed amorphous GeO2 up to 100 GPa by valence-to-core X-ray emission spectroscopy
Georg Spiekermann  1, 2, 3, *@  , Manuel Harder  3@  , Peter Zalden  4@  , Christoph Sahle  5@  , Max Wilke  1@  , Nicole Biedermann  4@  , Christopher Weis  6@  , Wolfgang Morgenroth  7@  , Eleonora Kulik  3, 8@  , Norimasa Nishiyama  9@  , Sylvain Petitgirard  8@  , Hasan Yavas  3@  , Christian Sternemann  6@  
1 : Potsdam University [Potsdam]
Karl-Liebknecht-Straße 24-25, 14476 Potsdam -  Germany
2 : GFZ Potsdam
Telegrafenberg, 14473 Potsdam -  Germany
3 : Deutsches Elektronen-Synchrotron [Hamburg]  (DESY)  -  Website
Notkestraße 85 D-22607 Hamburg -  Germany
4 : European XFEL
Holzkoppel 4, 22869 Schenefeld -  Germany
5 : European Synchrotron Radiation Facility  (ESRF)
European Synchrotron Radiation Facility, European Synchrotron Radiation Facility
6 : TU Dortmund
44221 Dortmund -  Germany
7 : Frankfurt University
Theodor-W.-Adorno-Platz 1, 60323 Frankfurt am Main -  Germany
8 : BGI Bayreuth
95440 Bayreuth -  Germany
9 : Tokyo Institute of Technology
2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8550, JAPAN -  Japan
* : Corresponding author

The application of valence-to-core X-ray emission spectroscopy (vtc-XES) to DAC experiments is a developing field of research. This probe allows insight into the pressure evolution of electron binding energies and electronic transition probabilities.

In the case of germanium oxides, this information can be extracted from the oxygen 2s -> germanium 1s crossover transition emission line, whose energy and intensity are directly proportional to the germanium coordination and the Ge-O bond distances, respectively. This makes vtc-XES a powerful tool for germanium oxides at high pressure, complementary to X-ray diffraction (XRD) and extended X-ray fine structure absorption spectroscopy (EXAFS) measurements. The information from measured and modeled vtc-XES spectra is extracted in a simple straight-forward way, without additional parameters or assumptions concerning density.

We compressed amorphous GeO2 up to 100 GPa in diamond anvil cells (DAC) and measured germanium valence-to-core X-ray emission spectra. The 6-fold coordination is reached at 20 GPa. At about 50 GPa, a further coordination increase is observed, and the average coordination reaches about seven at 100 GPa, in agreement with the recent XRD study of Kono et al. 2016.


Online user: 1 RSS Feed